Specification applies to all analyzers in the range unless a model number is specified.
Measurement parameters
Any of the following parameters can be measured and displayed:AC Functions
- Capacitance (C)
- Inductance (L)
- Resistance (R)
- Reactance (X)
- Conductance (G)
- Susceptance (B)
- Dissipation Factor (D)
- Quality Factor (Q)
- Impedance (Z)
- Admittance (Y)
- Phase Angle (Ø)
Display format
Series or parallel equivalent circuit.Test conditions
Frequency range
6520A 1 kHz to 15 MHz6530A 1 kHz to 50 MHz
6540A 1 kHz to 120 MHz
Accuracy of set frequency ±0.005%
AC Drive level
10 mV to 1V rms*200 µA to 20 mA rms*
*Varies with frequency
Signal source impedance: 50 Ω nominal
Automatic Level Control (ALC) maintains constant voltage or current at the device under test (DUT)
DC bias current (optional)
100 mA of DC bias current40 V of DC bias voltage
Mode of operation
Graphical sweep mode
Allows graphical sweep of any two measurement parametersSwept parameters: - frequency, drive level or DC bias
Meter mode
Allows the instrument to be used as a standard LCR meter.Setup data
Up to 20 instrument setups may be stored locally for each mode.Measurement connections
Four front panel BNC connectors permit two, three or four terminal connections with the screens at ground potential.Measurement accuracy
Dissipation factor±0.0005 (1+D2)*
Quality factor
±0.05 %( Q+1/Q)*
Capacitance / Inductance / Impedance
±0.05%*
*Varies with frequency, drive level and measured impedance
General
Power supply
Input voltage 90 V AC to 264 V AC (Autoranging)Mains frequency
47 to 63 HzDisplay
8.4″ VGA (640 x 480) colour TFT with touch panelLocal printer
HP-PCL compatible graphics printingCentronics / parallel printer port, Epson compatible text / ticket printing
Network printer
HP-PCL compatible graphics printingRemote trigger
Rear panel BNC with internal pull-up, operates on logic low or contact closureUSB interface
Two Universal Serial Bus InterfacesUSB 1.0 compliant
VGA interface
15-way D-type connector to drive an external monitor in addition to the internal screenNetwork interface
10/100-BASETX Ethernet controller.RJ45 connector
Keyboard interface
Standard USB or PS/2 keyboard port. Instrument front panel remains active with keyboard plugged in.Mouse interface
Standard USB or PS/2 mouse port.Touch screen remains enabled when the mouse is connected.
Bin handler (option)
Isolated (24 V) and non-isolated (5 V).25-way D-type connector
GPIB interface (option)
External instrument control 24 pin IEEE 488 connectorEnvironmental conditions
This equipment is intended for indoor use only in a non-explosive and non-corrosive atmosphere
Temperature Range
Storage -20°C to 60°COperating 0°C to 40°C
Full Accuracy 18°C to 28°C
Relative humidity
Up to 80% non-condensingAltitude
Up to 2000mInstallation category
II in accordance with IEC664Pollution degree
2 - mainly non-conductiveSafety
Complies with the requirements of EN61010-1EMC
Complies with EN61326 for emissions and immunityMechanical
Height 190 mm (7.5″)Width 440 mm (17.37″)
Depth 525 mm (20.5″)
Weight 13.8 kg (32 lb)